11/29/2009 · Notification Number RS_EXCEPTION 301 . Error when generating dataProvider. Diagnosis. Data provider could not be created in your Web application. System Response. Cannot start the Web application. Procedure. Check whether the data provider (query or query view) has been correctly specified in or deleted from the Web template.
This could include issues you have found that cause the messages to appear incorrectly as well as any fixes you have found or relevant SAP OSS notes. You will then be able to find this information quickly, simply by searching on the message class RS_EXCEPTION .
Can’t open anyone BEx query through Analyzer or RSRT (Message Number RS_EXCEPTION 301 )Hello everyone, I have the following problem. On a newly installed BW System with fillowing parameters: Posted on Jun 26, 2015 at 12:31 PM | 374 Views . Follow. RSS Feed. Answers Include Comments …
BW, Business Warehouse, L_REPID, CL_RSR_OLAP_VAR, L_INCLUDE, CONSTRUCTOR, L_SOURCE_LINE, 41, RS_EXCEPTION 301 , RS_ EXCEPTION301 , BRAIN_DEV 036, BRAIN_DEV036, BRAIN 635, BRAIN635, query has been changed and generated after current session was started, service cannot be used, query * could not be opened , KBA , bpc , BW.
RS_EXCEPTION 240, ENQUEUE_INTERNAL_DTAS of class CL_RSBK_DTP_V, RSENQ 151, RSENQ 002, rsenq002, RS_ EXCEPTION301 , RS_EXCEPTION 301 , migration, conversion, , KBA , BW-WHM-DST-DTP , Data Transfer Process , BW-WHM-DST , Data Staging , Problem, cl_rsdr_at_query >> row: inc: 54 prog: write_messages (rs_exception 301 ) The issue may happen after a database version upgrade. failed when executing a query> Read more…
About this page This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required). Search for additional results. Visit SAP Support Portal’s SAP Notes and KBA Search.
Near-line provider, &FEMS, method IF_RSDRV_VPROV_INT_QUERY~READ, message DBMAN305, RS_EXCEPTION000RS_EXCEPTION 000, RS_ EXCEPTION301 , RS_EXCEPTION 301 support package, nearline storage Related Notes :, 8/3/2015 · Hi, I have not seen any explanation WHY it happens.I have not seen any confirmation that it fix issue permanently.. Program mentioned is part of post migration step, i believe it is started after migration DB to HANA.
4/10/2020 · InfoObject uses Conversion Routine ALPHA. When you create a HCPR based on a Hana Calculation View (see Hana Model), it is possible to associate a field of the view with a BW Infoobject (see TransientProviders:Example II).It is important to check whether the data type of the field really matches the data type of the InfoObject, see Example.In addition you need to